4. Input/output signal settings

4. Input/output signal settings

4-1. Setting the SDI input signals and analog input signals

The user can set the SDI input signals and analog input signals.

IN5 to IN8 can be set only when one of the following optional boards has been connected: SDI input board

Analog input board

Analog composite input board

4-1-1. Setting the frame synchronizer

The frame synchronizer can be set to On or Off for each input.

The DVI input (option) frame synchronizer is permanently On. It cannot be set from On to Off or vice versa.

1Press the [FUNC] button to light its indicator, and press the [IN/OUT] button to display the IN/OUT menu.

2 Turn [F1] to display the Input sub menu.

3Turn [F2], select the input signals using the Signal item, turn [F3], and select On or Off for the frame synchronizer using the FS item.

If the output signal phase is set to 0H, Off cannot be selected as the FS item setting.

<Menu display>

Input

 

Signal

 

FS

 

 

Mode↓

 

AnaGain

1/15

 

In1

 

 

On

 

]Normal

 

0

 

 

 

 

IN1-8

Off

D by D −30-+30

UC Auto

AVDL function is active while the frame synchronizer function is set to Off.

The AVDL function automatically adjusts the input image signal phase to the horizontal synchronization reference signal phase.

For details, refer to “4-6. Adjusting the output signal phase”.