4. Input/output signal settings

4-2. Setting the up-converter (option)

Select the settings for the up-converter that is built into the optional boards listed below. SDI input board

Analog input board

Analog composite input board

1Press the [FUNC] button to light its indicator, and press the [IN/OUT] button to display the IN/OUT menu.

2Turn [F1] to display the UpConvt sub menu.

An asterisk (]) appears at the left of the parameter currently selected.

<Menu display>

UpConvt Signal Scale↓ MovDet↓ Sharp↓

13/15 IN5 ]SQ ]3 ]3

IN5-8

EC

 

LB

1-5

1-5

3Turn [F2] to select the input signal using the Signal item.

4Turn [F3] to select the scaling system using the Scale item, and press the [F3] switch to enter the selection. SQ (squeeze): The image is enlarged both horizontally and vertically to fill the entire screen.

EC (edge crop): The aspect ratio of the image is maintained, the image size is increased in accordance with the vertical resolution, and black bands are added at the left and right.

LB (letter box): The aspect ratio of the image is maintained, the image size is increased in accordance with the horizontal resolution, and the image is cropped at the top and bottom.

Input image

SQ

EC

LB

5Turn [F4] to set the image movement detection sensitivity using the MovDet item, and press the [F4] switch to enter the selection.

1: Toward still images 3: standard 5: toward moving images

6Turn [F5] to set the extent of the edge sharpness for the images using the Sharp item, and press the [F5] switch to enter the selection.

1: Not sharp edges 3: standard 5: very sharp edges

For details on the other settings, refer to the operating instructions of the optional board.