6. External interfaces

6-2. GPI connector

These connectors enable the unit to be controlled from an external source. Signals are input using contacts. The following types of control are exercised using the contacts as triggers. Use stereo mini plugs with a 3.5 mm diameter for connection to the unit.

<Control functions that can be assigned>

GPI2

GPI1

COMMON

Function assigned

Description of control

Remarks

AUTO

Control exercised using AUTO button on unit’s panel

 

 

 

 

CUT

Control exercised using CUT button on unit’s panel

 

 

 

 

DSK

Control exercised using DSK button on unit’s panel

 

 

 

 

PinP

Control exercised using PinP button on unit’s panel

 

 

 

 

FTB

Control exercised using FTB button on unit’s panel

 

 

 

 

BGDAUTO

Auto transition control for background

Control is exercised regardless

BGDCUT

Cut transition control for background

of the selection statuses of the

switches and buttons on the unit’s

KEYAUTO

Auto transition control for key

panel.

KEYCUT

Cut transition control for key

 

<Initial setting>

Port

Function assigned

Description of control

GPI1

AUTO

Control exercised using AUTO button on unit’s panel

GPI2

DSK

Control exercised using DSK button on unit’s panel

Use the GPI sub menu under the SYSTEM menu to set the functions to be controlled using the external switches connected to the GPI ports and to enable or disable the control using the external switches.

For details on the settings, see 5-6-4.

101

Page 101
Image 101