Cable Compensator AW-RC400

Specifications

 

 

 

Supply voltage:

DC 10.8V to 16V

 

Power consumption:

Approx. 9W

 

 

 

 

 

 

1 indicates safety information.

Input connectors

 

 

DC 12V IN:

For connecting accessory AC adaptor (AW-PS301)

G/L IN:

BNC!2, automatically terminated by 75-ohm resistance, loop-through output, black burst

VIDEO/Y, Pr/C, Pb:

BNC!3 (5 sets), 75-ohm termination

 

Composite 1 Vp-p

 

Y/C

 

Y: 1 Vp-p (with sync)

 

C: 0.286V (burst)

 

Component

 

Y: 1 Vp-p (with sync)

 

Pr, Pb: 0.7Vp-p

MONI SEL IN:

RJ45

 

Connecting cable: 10BASE-T straight cable (UTP category 5), max. 50 meters

Output connectors

 

 

G/L OUT:

BNC!5, 75-ohm output, 5C-2V connecting cable, max. 1000 meters

VIDEO/Y, Pr/C, Pb:

BNC!3 (5 sets), 75-ohm output

 

Composite 1 Vp-p

 

Y/C

 

Y: 1 Vp-p (with sync)

 

C: 0.286V (burst)

 

Component

 

Y: 1 Vp-p (with sync)

 

Pr, Pb: 0.7Vp-p

 

(Cable compensation adjustment is required)

MONITOR OUT1/2:

BNC!3 (2 sets), 75-ohm output

Switch and adjustment functions: Power ON/OFF; cable length setting 0/1/2/3/4/5; sync signal setting SHORT/LONG; cable compensation amount adjustment; video level adjustment

Ambient operating temperature:

0°C to +40°C

Storage temperature:

–20°C to +60°C

Ambient operating humidity:

30% to 90% (no condensation)

Dimensions (W!H!D):

420!250!88 mm

Weight:

Approx. 3.7 kg

Finish:

AV ivory paint (colour resembling Munsell 7.9Y6.8/0.8)