CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE

Table (b): Outdoor Air Temperature Shifting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode:

 

Outdoor Temperature, X (°C):

 

 

Temperature Shift (°C)

 

 

 

 

 

 

 

 

 

 

 

 

CS-HE9DKE

 

 

CS-HE12DKE

 

 

Cooling/Soft Dry

 

 

 

38

X

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

30

X

38

 

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

23

X

30

 

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

 

 

X

23

 

 

0.00

 

 

0.00

 

 

 

 

Heating

 

 

 

21

X

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

17

X

21

 

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

9

X

17

 

 

0.00

 

 

0.00

 

 

 

 

 

 

 

 

5

X

9

 

 

+0.50

 

 

+1.00

 

 

 

 

 

 

 

 

1

X

5

 

 

+1.00

 

 

+1.25

 

 

 

 

 

 

 

 

 

 

X

1

 

 

+1.50

 

 

+2.00

 

 

 

Table (c): Fan Speed Shifting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode:

 

 

 

Fan Speed:

 

Temperature Shift (°C)

 

 

 

 

Cooling

 

 

 

All

 

 

+1.25

 

 

 

 

 

Soft Dry

 

 

 

All

 

 

+1.0

 

 

 

 

 

Heating

 

 

 

Lo

 

 

+1.0

 

 

 

 

 

 

 

 

 

 

 

Hi, Me-, Me, Me+, Auto

 

+0.25 (CS-HE9DKE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+0.50 (CS-HE12DKE)

 

 

Table (d): Start-Up Shifting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode within 60 Minutes from Start-up:

 

Temperature Shift (°C)

 

 

Cooling/Soft Dry

 

 

 

 

 

 

 

 

-1.0

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

+2.0

 

 

 

9.2.Indoor Power Relay Control

The Power Relay turns on under the following conditions.

1.For three minutes, when plugged in the A/C or the Error Reset button on remote controller is pressed.

2.During Installation Check Mode and following for three minutes after checking.

3.During On-timer sampling and during Preliminary operation.

4.During Operation and following for three minutes after the operation is stopped.

5.During Auto Operation, Test run, Forced Heating or Odour Removal Operation and following for three minutes after the operation is stopped.

21