CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE

9.4.Airflow Direction Control

9.4.1.Horizontal and Vertical Directions

Vertical louver is controlled by remote control: the Vertical Airflow Direction button on the remote controller and by each operation mode, as shown in the table below.

Cooling Operation Mode

Manual Operation

 

Vertical Automatic Operation

Powerful-ON

 

 

 

•• After Powerful is turned on, the louver is

 

••

The louver swings between the upper limit

fixed at 26° for 5 minutes or until the Neural

•• Five-level setting is possible with the remote

 

and the lower limit.

Control is stabilized.

 

 

 

controller.

 

 

 

 

 

 

•• After the Neural Control is stabilized, the

 

 

 

louver is fixed at 12°.

 

 

 

 

 

 

 

 

 

 

Dry Operation Mode

 

Manual Operation

 

Vertical Automatic Operation

Power-ON (Automatic Operation)

 

••

The louver is fixed at 12°.

•• The louver is fixed at 12°.

•• Five-level setting is possible with the remote

 

 

 

controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

Ion Operation Mode

 

Manual Operation

 

Vertical Automatic Operation

Power-ON (Automatic Operation)

 

•• The louver swings between the upper limit

•• The louver is fixed at 12°.

 

 

•• Five-level setting is possible with the remote

 

and the lower limit.

 

 

 

 

controller.

 

 

 

 

 

 

 

23