CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE

Fig. 17

13.3.2.6. Removal of Vacuum Pump

1.Remove the Cabinet Top Plate and Cabinet Front Plate according to 13.3.2.1.

2.Remove the Control Cover and Terminal Cover according to 13.3.2.2.

3.Remove the screws (two) fixing Terminal part and the Cabinet Side Plate.

Fig. 18

4.Remove the Cabinet Side Plate by removing the screws (five).

••A screw of among the five is under the back side of the Outdoor unit.

Fig. 19

5.Disconnect the cable of the Vacuum Pump from the Connector (white).

6.Disconnect the hose from the Vacuum Pump by loosening the clip with tools such as pliers.

Note: Do not remove the connecting materials (Black rubber) on the intake side from the hose.

Fig. 20

••Connect two hoses correctly when reassembling the Vacuum Pump. Incorrect connection may cause failure.

7.Remove the screws (three) for the Vacuum Pump.

Fig. 21

8.Remove the Vacuum Pump by holding up the backside of the Vacuum Pump Holder a little and pulling it in with inclined to the left side.

Fig. 22

80