13.3.1.5.Removal of Oxygen Discharge Outlet

1.Remove the Front Grille according to the procedure 13.3.1.1.

2.Remove the Oxygen Discharge Outlet from the Heat Exchanger and remove the Oxygen Tube by releasing the hooks (four) on the plastic part.

Note: The Oxygen Discharge Outlet is on the left side.

CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE

Fig. 25

Fig. 22

Fig. 23

13.3.1.6.Removal of Air Swing Motors for Vertical and Horizontal Louvers

1.Remove the Front Grille according to the procedure 13.3.1.1.

2.Remove the Discharge Grille.

Note: Pulling up the Discharge Grille a little can make the Drain Hose easy to be removed.

••The Air Swing Motor for Vertical Louver can be removed without removal of the Discharge Grille.

13.3.1.7. Removal of Ventilation Motor

1.Remove the Front Grille according to the procedure 13.3.1.1.

2.Remove the Connector (white) for the Ventilation Motor and the screws (two).

Fig. 26

Fig. 27

3.Pulling out the Ventilation Motor by releasing the hook (one).

Note: The Fan Joint Duct Part under the Ventilation Motor can not be removed. Remove the Indoor unit from the Chassis Complete for servicing.

Fig. 24

3.Remove the Motors by removing the screws (one each) for the Motors and the cable connector.

Fig. 28

75