→Cooling, Heating, Dry or Ionizing Air Cleaning Operation
••When "Oxygen" is selected with the Switch during Ionizing Air Cleaning Operation + Simultaneous Oxygen Enrich Operation,
→Ionizing Air Cleaning Operation
2.Common use with ON/OFF Timer
••When
→In last time operation, if unit is stopped in Single Oxygen Enrich Operation, it operates in Single Oxygen Enrich mode.→ In last time operation, if unit is stopped in operations other than Single Oxygen Enrich, it operates at its operation mode.
••When
→Unit remains the operation.
••When
→Unit stops operating.
••Preliminary Operation of Single Oxygen Enrich Operation
→Not applicable.
9.13.5. Oxygen Monitor DisplayMonitor level | 0 | 1 | 2 | 3 |
Status | Stop | Stop (Vacuum pump | — | In operation |
|
| operation) |
|
|
LED Display | OFF | Blinking | — | ON |
Oxygen requirement level | 0 | 0 | — | 3 |
••Monitor level when installation (Oxygen) is checked is "3".
9.13.6. Oxygen Enrich Control•• Vacuum pump is operated after Oxygen requirement level that is decided in outdoor unit from Oxygen supply level decided in indoor unit and protective control devices such as a vacuum pump.
Oxygen Requirement | Oxygen Supply Level | Vacuum pump operation time | |
Level |
|
|
|
| |||
0 | 0 | 10 | 0 |
— | 1 | 7 | 3 |
— | 2 | 4 | 6 |
3 | 3 | 0 | 10 |
•• Operating cycle period of Vacuum pump: 10 minutes; Oxygen supply level is renewed in a cycle.