Indication of lamp monitor

This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem.

Turn the power off and follow the steps below.

Power indicator

Lamp 2 monitor (LAMP 2)

Lamp 1 monitor (LAMP 1)

Temperature monitor (TEMP) indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name of monitor

 

 

Lamp

 

 

Information

 

 

 

Checkpoint

 

 

Remedial measure

 

 

lamp

 

 

indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you turn on the

 

 

• Wait about five minutes in the

 

 

 

 

 

 

 

 

 

 

 

power when the

 

 

current status.

 

 

 

 

 

Lighting in

 

 

Warm-up status

 

 

ambient temperature

 

 

• Install the unit in a location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

was low

 

 

having an ambient

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(approx. 0 °C)?

 

 

temperature from 0 to 45 °C.

 

 

 

 

 

(lamp unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High temperature

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

• Remove the object that is

 

 

 

 

 

 

 

inside. (WARNING)

 

 

 

 

 

 

 

 

 

monitor

 

 

 

 

 

 

 

• Check if the

 

 

blocking the ventilation port.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Move the projector to a

 

 

 

 

 

 

 

 

 

 

 

ventilation port is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMP

 

 

 

 

 

 

 

 

 

 

temperature of 0 to 45 ˚C and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

 

 

 

 

 

blocked.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the humidity of 20 to 80 % (no

 

 

 

 

 

red

 

 

The filter is clogged.

 

 

• Is the room air

 

 

 

 

 

 

 

 

 

 

 

 

 

condensation).

 

 

 

 

 

(1 time)

 

 

 

 

 

temperature too high?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Turn off the MAIN POWER

 

 

 

 

 

 

 

 

 

 

 

• Is the air filter clogged

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

 

 

High temperature

 

 

with dust?

 

 

 

 

 

 

 

 

 

 

 

 

 

page 23 and clean the air filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

red

 

 

inside

 

 

 

 

 

 

 

(refer to page 41).

 

 

 

 

 

(2 times)

 

 

(Standby condition)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

 

 

 

 

 

 

 

 

 

 

• Turn off the main power supply

 

 

 

 

 

 

Cooling fan has

 

 

 

 

 

 

 

(MAIN POWER) switch in the

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

been stopped.

 

 

 

 

 

 

 

procedure shown on page 23

 

 

 

 

 

(3 times)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and consult the distributor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you notice a

 

 

• This lamp monitor lights up

 

 

 

 

 

 

 

 

 

 

 

 

when the lamp unit used hours

 

 

 

 

 

 

 

 

 

 

 

“REPLACE LAMP”

 

 

 

 

 

 

 

 

 

 

Indicates the time

 

 

 

 

have reached 1 300 hours

 

 

 

 

 

Lighting in

 

 

 

 

message on the

 

 

 

 

 

 

 

 

 

for replacing the

 

 

 

 

(3 800 hours when long life

 

 

 

 

 

red

 

 

 

 

screen when turning

 

 

 

 

 

 

 

 

 

lamp unit.

 

 

 

 

lamp units are used). Request

 

 

 

 

 

 

 

 

 

 

on the projector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the dealer to replace the lamp

 

 

Lamp monitor

 

 

 

 

 

 

 

 

power supply?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP1 LAMP2

 

 

 

 

 

 

 

 

• Did you turn the power

 

 

• Wait until the lamp has cooled

 

 

 

 

 

 

 

 

 

 

back on immediately

 

 

off, and then turn on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

after turning it off?

 

 

power.

 

 

 

 

 

Blinking in

 

 

Error is detected in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Some error has

 

 

 

 

 

 

 

 

red

 

 

the lamp or lamp

 

 

arisen in the lamp

 

 

• Turn off the MAIN POWER

 

 

 

 

 

(3 times)

 

 

power.

 

 

circuit.

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

 

 

• Check for fluctuation

 

 

page 23 and consult the

 

 

 

 

 

 

 

 

 

 

 

(or drop) in the source

 

 

dealer.

 

 

 

 

 

 

 

 

 

 

 

voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attention • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 22, 23.

If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your dealer.

40

Page 40
Image 40
Panasonic PT-D5600EL, PT-DW5000EL, PT-DW5000E manual Indication of lamp monitor