Indicators

There are two indicators on the front of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.

LAMP indicator

TEMP indicator

Indicator name

Indicator display

Problem

 

 

The internal

 

 

projector

 

 

temperature is too

 

Illuminated (red)

high.

TEMP indicator

 

 

 

 

The metal halide lamp

TEMP

 

has turned off

 

automatically because

 

Flashing (red)

 

the internal

 

 

temperature has risen

 

 

to an abnormally high

 

 

level.

Possible cause

Remedy

The ventilation holes

Uncover the ventilation holes.

may be covered.

 

The ambient

Set up the projector in a place

temperature in the

where the temperature is between

place of use may

41°F (5°C) and 104°F (40°C)

be too high.

and the humidity is between 10%

 

and 80% (with no condensation).

The air filter may

Turn off the main power

be blocked.

supply by following the

 

procedure on page 11, and

 

then clean the air filter (refer

 

to page 39).

Illuminated (red)

LAMP indicator

LAMP

Flashing (red)

 

It is nearly time to replace the lamp unit.

The metal halide lamp switches off automatically.

Does “LAMP” appear on the screen after the projector is turned on?

The power may have been turned on immediately after it was turned off.

There may be an abnormality in the lamp circuit.

This occurs when the operation time for the lamp unit is nearing 1,800 hours. Ask your dealer or an Authorized Service Center to replace the lamp unit.

Wait for a while until the lamp unit cools down before turning the power back on again.

Turn off the main power supply by following the procedure on page 11, and then contact an Authorized Service Center.

NOTE:

Be sure to turn off the main power by following the procedure given in “Turning the power on and off” on page 11 before carrying out any of the procedures in the “Remedy” column.

If the main power turns off after the TEMP indicator starts flashing, it means that an abnormality has occurred. Please contact an Authorized Service Center so that the necessary repairs can be made.