Operation modes

How to operate the controller 1) Setting irradiation conditions

Setting the irradiation intensity and irradiation time separately for each of CH1 to CH4.

￿The displayed values apply to the flashing channel.

1. Selecting channels

Select the channel to be set by pressing CH1 to CH4. The selected channel is indicated by a green light (flashing or still).

*It is not possible to select a CH unless an LED head is connected to it.

2.Setting irradiation intensity

Hold down the SET switch to select the CH to be set. (The selected channel is indicated by a green light.) Initially, only “%” (intensity) appears in the green (7-seg) display. Use △/▽ to set the desired intensity value, then press SET again to confirm. Note that while setting the irradiation intensity you can press the EMISSION switch to start UV irradiation. This makes it easy to make adjustments.

3. Setting irradiation intensity

When you have finished setting the intensity, the green display will automatically display only “sec.” Use △/▽ to set the desired time value, then press the SET switch again to confirm. Note that if you use

to decrease the setting below “0.0 sec” the displa y will show “Con.” At this setting irradiation will be continuous with no time limit.

4.Completing settings

After setting irradiation time and pressing SET the controller will return to Operation mode. To continue settings for other channels, repeat the procedure above from step 1 for each channel you wish to set.

(It is possible to switch the display even during irradiation. The displayed values are stored in memory even when the controller is powered off. After the controller is powered on again it will restore the display to its last state. Note, however, that unless a channel is selected nothing will be appeared on the display.)

2) Timer irradiation

Irradiation using the EMISSION switch of the controller

￿The displayed values apply to the flashing channel.

(1) Starting irradiation

1.

Select the channel/s for irradiation.

 

2.

Press the EMISSION switch

(Irradiation will start on all the active channels (green indicator). The EMISSION switch glows red during irradiation.)

* Irradiation stops after irradiation is finished on all ch

annels.

(2) Stopping irradiation

3. While irradiation is in progress press the EMISSION switch again.

 

(Irradiation will stop on all channels.)