External control
6.Using the AUTO screen (only available in online mode)
…Displays all UJ35 controller information in real time.
…Enables irradiation START/STOP and emergency STOP control from computer.
| • LED status for each CH differentiated by color |
| • When irradiation is possible, READY ON is highlig hted |
| • If an error occurs, an error number is displayed |
| • Panel showing error list can be displayed at any time |
| • During irradiation START is highlighted |
・[TYPE] | Shows current TYPE |
・[STEP] | During irradiation, current STEP is displayed. |
・[TIME(s)] | During irradiation, counts down the time remaining from the value that was set for the current STEP. |
| Continuous irradiation: Indicates the total irradiation time (so far) for the current step |
・[UV.PWR(%)] | During irradiation shows the UV strength for the current STEP. |
・[TEMP.] | Constantly shows the LED temperature for each connected CH. |
・[Replacement time(h)] | Shows the LED head replacement time setting |
・[Remaining time before replacement (h)] Shows remaining LED head life to when replacement is necessary.
・[ERROR No.] | When an error occurs, error number is displayed. |
・[Total Irradiation time (h)] Shows cumulative time that LED head has been ON. | |
・[CH SELECT] | Uploads CH selection to the UJ35 controller. |
・BUSY ON/OFF | Indicates BUSY ON/OFF status of each channel. |
・READY ON/OFF | Indicates READY ALL ON/OFF status. |
| Also, indicates READY ON/OFF status of each channel. |
・START | Starts irradiation on all selected channels together. |
| Also used to start irradiation on individual channels. |
・STOP | During irradiation, performs emergency stop. |
・RESET | Resets errors. |
・ERROR No. | Displays error list panel. |
44