Specifications

UV sensor specifications

Item

 

 

ANUJ3800

 

 

 

 

UV intensity

 

High range

0 to 49.9 W/cm2 (min. reading 0.1 W/cm2)

measurement range

 

Low range

2

2

 

 

0 to 9.99 W/cm

(min. reading 0.01 W/cm )

Measurement precision

 

±5% (+5 to +35°C)

 

±1% (at 25°C, repeatability)

 

 

 

 

 

 

Data communication

 

RS-422 level communication, proprietary format, 9,600 bps

 

 

 

Power supply voltage

 

8.1 to 13.2 V DC

 

 

 

 

Power consumption

 

30 mA

 

 

 

 

Operating temperature/humidity

+5 to +35°C, 30 to 85% RH (at 25°C, no condensation)

range

 

 

 

 

Storage temperature/humidity

–10 to +60°C, 30 to 85% RH (at 25°C, no condensation)

range

 

 

 

 

Connector

 

mini-DIN connector (TECHNICAL DENSHI D6-175J-201)

 

 

 

 

Weight

 

Approx. 220 g (Body + sensor head + 2 m connection cable)

 

Approx. 350 g (incl. packaging)

 

 

 

 

 

 

Accessories

 

2 m connection cable, INSTRUCTION MANUAL

 

 

 

 

 

52