External control

 

Product type switching table

 

 

 

 

 

 

 

Type No.

 

Pin No.7

 

Pin No.6

 

Pin No.5

Remark

 

 

 

 

 

 

 

 

 

 

 

 

0

 

OFF

 

OFF

 

OFF

Product type switching is enabled when all

 

 

 

 

pins are off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

OFF

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

OFF

 

ON

 

OFF

When an external signal is on, the product

 

 

 

 

 

 

 

 

 

 

 

3

 

OFF

 

ON

 

ON

 

type set by the external signal has priority.

 

 

 

 

 

 

 

 

 

 

 

 

4

 

ON

 

 

OFF

 

OFF

* The green display will show a flashing “.”

 

5

 

ON

 

 

OFF

 

ON

 

(period). Irradiation intensity and irradiation

 

 

 

 

 

 

time settings cannot be performed using the

 

 

 

 

 

 

 

 

 

 

 

6

 

ON

 

 

ON

 

OFF

controller.

 

 

 

 

 

 

 

 

 

 

 

 

7

 

ON

 

 

ON

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation via external signals

Output SpecificationRated load voltage: 5 V DC to 28 V DCMax. load current: 100 mA (per 1 output)

When 5 V internal voltage is used, set the total of maximum load current to less than 250mA.

Maximum voltage drop is less than 0.9 V when output is given.

25