Wire stripping length
7 External control

7.1External input/output control

External control connectors (12 pin × 2) MINI COMBICON Plug 12P

(PHOENIX CONTACT: MC 1.5/12-ST-3.5)

(Osada: OS-85-12P)

Compatible wiring (stranded)

 

Size

 

 

Conductor section area

 

 

 

 

 

 

 

 

 

 

 

6-7 mm

 

 

AWG#24-16

 

0.2 - 1.25 mm2

 

 

 

 

 

 

 

 

 

Warning

Tightening torque: 0.22 to 0.25 Nm

 

Precautions for wiring

Carefully strip the cover so as not to damage the core wires.

Connect the core wires without twisting them.

Connect the core wires without soldering them; otherwise, they may break due to vibration.

After connection, do not apply stress to the cable.

Because of the terminal structure, if the wire is tightened by a counterclockwise rotation, the connection will fail. In such cases, pull out the wire, check the terminal hole, and then connect it again.

Input/output terminal table

INPUT

Pin No

Signal name

Description

 

1

START

1

CH1 irradiation start signal

 

2

START

2

CH2 irradiation start signal

 

3

START

3

CH3 irradiation start signal

 

4

START

4

CH4 irradiation start signal

 

5

TYPE

Chg1

Product type switching signal

 

6

TYPE

Chg2

Product type switching signal

UJ35 only

7

TYPE

Chg3

Product type switching signal

 

8

UV CHECK

UV intensity control mode signal

 

9

STOP

 

Irradiation stop signal, Error reset

 

10

START ALL

CH1-CH4 irradiation start signal

 

11

INTERLOCK

Interlock (normally ON)

 

12

COM

 

Common terminal for input/output signals

 

OUTPUT

Pin No

Signal name

Description

 

13

READY ALL

ON when irradiation is ready to start

 

14

READY1/BUSY1

ON when CH1 irradiation is ready to start/in progress

READY/BUSY

15

READY2/BUSY2

ON when CH2 irradiation is ready to start/in progress

singal is changed

16

READY3/BUSY3

ON when CH3 irradiation is ready to start/in progress

over by changing the

17

READY4/BUSY4

ON when CH4 irradiation is ready to start/in progress

initial setting mode.

 

18

ERROR

Error signal

 

19

ALARM

Warning signal (temperature/time warning)

 

20

COM

Common terminal for input/output signals

 

21

COM

Common terminal for input/output signals

 

22

FG

Frame gland

 

23

+5V

5 V DC output (for display or output signals)

 

24

COM

Common terminal for input/output signals

 

* Pin Nos. 12, 20, 21 and 24 are connected internally.

Warning The ON time of input signal pulses must be 100 ms or more.

24