Connections with any Existing Network System

ERROR

ALARM

STOP

PLAY

REC

RESET STILL SEQUENCE

ALARM

1

2

3

4

5

 

ESC

COPY 2

HDD

 

 

 

 

 

MENU

PAUSE REV FWD

SKIP

TIMER

6

7

8

9

0

 

SET

 

OPERATE

Digital Disk Recorder WJ-RT 208

IP Address: 192.168.0.88

LAN cable

Subnet Mask: 255.255.255.0

(Not provided: 10BASE-T/100BASE-Tx, Category 5, Straight)

Gateway Address: 192.168.0.1

 

 

 

 

 

HUB/Router

 

IP Address: 192.168.0.1

 

Subnet Mask: 255.255.255.0

Microsoft

 

Windowsxp

LAN

 

PC/AT Compatible

Microsoft

Windowsxp

IP Address: 192.168.0.x (x except 0, 1, 88, 255)

 

Subnet Mask: 255.255.255.0

 

Gateway Address: 192.168.0.1

 

 

PC/AT Compatible

Connections with a Broadband WAN Network

ERROR

ALARM

STOP

PLAY

REC

RESET STILL SEQUENCE

ALARM

1

2

3

4

5

 

ESC

COPY 2

HDD

 

 

 

 

 

MENU

PAUSE REV FWD

SKIP

TIMER

6

7

8

9

0

 

SET

 

OPERATE

Digital Disk Recorder WJ-RT 208

Server Port: 2000 (changeable)

Alarm Port: 4000 (changeable)

Broadband router A

Forward (WAN DVR)

UDP Port: 9998 (fixed)

TCP Port: 2000 (depends on the recorder settings)

WAN

Microsoft

Windowsxp

PC/AT Compatible

Broadband router B

Forward (WAN PC)

UDP Port: 999 (fixed)

TCP Port: 4000 (depends on the recorder settings)

Notes:

1.Broadband router A can only connect one WJ-RT208. (Each WJ-RT208 should be assigned a Global IP address.)

2.Broadband router B can only connect one PC/AT compatible machine. (Each compatible machine should be assigned a global IP address.)

Caution: The number of clients that can be connected to each WJ-RT208 is defined in the next table. According to differences in the network communication protocol, the number of clients that can be connected can differ. In the next table, the num- ber of clients that can be connected is defined for the TCP/UDP protocol and the MCAST protocol, independently of each other.

User type

TCP/UDP

MCAST

Manager

1 person

1 person

 

 

 

Remote monitoring

8 persons

Unlimited in the same subnet

 

 

 

Remote playback/net backup

1 person

1 person

 

 

 

Frame play

4 persons

Frame play not available

 

 

 

Remote talk

1 person

1 person

 

 

 

17