•When an event occurs, the monitoring images of its channel are displayed in the spot screen.
The spot screen is set up with the menu specified below.
•Recording when an event occurs
When there is an alarm, recording is automatically car- ried out during the setup time. In the state of Video Loss, no recording is carried out. This time setting is made with the menu shown below.
•Buzzer
The [ALARM] indicator blinks when an alarm is activat- ed, and this buzzer sounds.
The buzzer is set up with the menu specified below.
•An alarm signal output is generated from the TERMI- NAL/CONTROL port of the rear panel to the port of the preset number. The [ALARM] indicator blinks. The out- put port number of Alarm Output is set up with the menu specified below.
•Camera turning direction preset position
The camera preset position is set up with the menu specified below.
In regard to camera’s preset position setup, refer to "2.5.6 Register preset position of cameras" on page 30.
Notes:
1.This recorder is designed to start recording upon termi- nal input or on motion detection. When an alarm occurs in the process of recording images from the channel for which "TERMINAL REC" and "VMD REC" are set, only alarm actions such as event recording or event status display will be performed. Image quality for recording (Rec. Quality), frame rate and stream type will not auto- matically be changed.
2.If another alarm occurs again in the same channel with- in the time period that has been preset with "Alarm Time", the alarm is stopped after the lapse of the preset time period. (The alarm time period is not extended.)
3.Even though an alarm occurs, no automatic recording is carried out unless "Period1" or "Period2" of "TERMI- NAL REC" and "VMD REC" has been set at "On".
4.Information about external alarms is directly sent to the PC through the network. It has no relation to the "TER- MINAL REC" and "VMD REC" setting at the recorder. Please refer to <<Network Operating Instructions.pdf>> on the
5.When "Full" is selected for "Frame Rate", performing playback, recording of all channels and transmission of all channels of Net Client in parallel for many hours may stop image processing. In this case, recording will be continued, though few frames may be dropped.
2.4.3 Cancellation of alarm
When the [ALARM RESET] button is pressed, the alarm is cancelled. The [ALARM] indicator goes off.
Notes:
1.Recording is continued even though this alarm is can- celled.
2.The alarm cannot be cancelled while a menu is dis- played.
Close the menu, and then press the [ALARM RESET] button to cancel the alarm.
2.5 Camera Control
(1)Press the [MENU] button.
SYSTEM MANAGEMENT
SEARCH
REC&EVENT SETUP
PTZ SETUP
CAMERA SETUP
COMMUNICATION SETUP
REPORT
USER INFORMATION
DATA MANAGEMENT
(2)Move the cursor to "PTZ SETUP" and press the [SET] button.
The "PTZ SETUP" menu appears.
PTZ SETUP
PTZ SELECT
PRESET INFORMATION
28