Channel Name: Indicates the correlation between the camera title and serial number. Channel name can be changed using the provided software.
Cautions: For the [All] operation and functions, refer to the timer recording explanation.
Notes:
1."CH Enable" of channel 1 cannot be set at "Off". During playback in channel 1, it is impossible to set up its masking area.
Mask Enable:
"On": Used to enable masking area setup. The masked area will not be displayed and recorded (Black screen will be recorded.).
"Off": The masking function is not effective.
2.During operation in sequence mode, "CH Enable" can- not be set up.
3.When the setup value for "Rec. Reserve" exceeds one day, the screen data for a maximum of "preset number of days + 4 hours" can be reserved.
4."Mask Area" can be set up with the procedures speci- fied below.
Move the cursor to "Set" of "Mask Area" and press the [SET] button. The masking area setup screen is then opened.
Mask area
Start position
End position
a)The red cursor in the above diagram indicates the starting position and the black cursor indicates the ending position. When the direction button is used, it is possible to move both the red and black cur- sors simultaneously throughout the area. It is also possible to move the black cursor only to adjust the area size. Determine if you make a control mode changeover by pressing the [SET] button, moving the red and black cursors at the same time, or mov- ing the black cursor only.
b)When Numeral 1 is pressed, the profile of the mask- ing area is displayed. When 2 is pressed, all the area is embedded.
3.1.6Communication setup (COMMUNICA-
TION SETUP)
Network setup (NETWORK SETUP)
Move the cursor to "COMMUNICATION SETUP" on "WJ- RT208 SETUP MENU" and press the [SET] button.
COMMUNICATION SETUP
NETWORK SETUP
RS485 SETUP
DATA PORT SETUP
Move the cursor to "NETWORK SETUP" and press the [SET] button.
| NETWORK SETUP | ||||||
|
|
|
|
| |||
IP Address | 192.168.000.088 |
|
|
| |||
|
|
|
|
| |||
Subnet Mask | 255.255.255.000 |
|
|
| |||
|
|
|
|
| |||
Gateway | 192.168.000.088 |
|
|
| |||
|
|
|
|
|
|
|
|
Server Port | 2000 |
|
|
| |||
|
|
|
|
| |||
Protocol |
| TCP |
| ||||
|
|
|
|
| |||
Alarm Center IP | 192.168.000.188 |
|
|
| |||
|
|
|
|
| |||
Alarm Port | 4000 |
|
|
| |||
|
|
|
|
| |||
Alarm Enable |
| Off |
| ||||
|
|
| |||||
Line Speed | Auto Mode |
|
| ||||
|
|
|
|
|
|
|
|
| OK |
|
| Cancel |
|
|
|
|
|
|
|
|
|
|
|
IP Address: IP address given to this unit
Subnet Mask: Subnet mask for this unit
Gateway: Gateway address for this unit
Server Port: Port number of this unit
Protocol: Communication protocol
Alarm Center IP: IP address of the PC on which the Alarm Center is installed
Alarm Port: Communication port number of the alarm center, 1024 - 9999
Default: [4000] Alarm Enable: "On" or "Off"
Default: "Off"
Line Speed: Communication speed of the network card is set up to match network communications.
Notes:
1.In regard to initial setting and setup enabled range, refer to "Parameters and initial setup values for the setup menu."
2.It is necessary to restart the unit after changing the set- tings.