Balcar R410A Concealed Duct type, 183, Deodorant Filter, Ammonium Filter, Safety Cautions, Notes

Models: R410A

1 109
Download 109 pages 54.47 Kb
Page 107
Image 107
Deodorant Filter, Ammonium Filter

Concealed Duct type

Deodorant Filter, Ammonium Filter

Installation Manual

Installation of filter sold separately

 

 

1 Remove the air filter, and install a filter sold separately to the

 

Filter sold

suction port.

 

separately

Push the filter sold separately completely up to the end.

 

 

Check that the rear side is hanged to the hook.

 

 

2 Install the air filter

Indoor unit

Hook

Be sure to fix the air filter with clamps in order to prevent falling.

 

 

Filter sold separately

(Clamps are attached to the indoor unit.)

 

 

 

• Deodorant filter

Deodorant Filter

Model: TCB-DF11BE

 

TCB-DF21BE

 

TCB-DF31BE

NOTES

NOTE

• Ammonium filter

Air filter

These filter cannot be reused even if it is washed.

 

TCB-DF41BE

Ammonium Filter

Model: TCB-DF11BE-AM

 

TCB-DF21BE-AM

 

TCB-DF31BE-AM

 

TCB-DF41BE-AM

Do not unpack the filter until you use it. (Otherwise, life of the deodorant filter or ammonium filter is shortened.)

Keep this Manual with Owner’s Manual of the indoor unit.

Maintenance of filter sold separately

• Clean the filter sold separately once per 2 months.

1 Take out the filter sold separately in the reverse order of “Installation of filter sold separately”.

2 Sweep away the dust of the filter sold separately with a cleaner.

3

To install a filter sold separately, be sure to set the fan referring the following description.

*The filter sold separately cannot be installed to an air conditioner built in with auxiliary electric heater.

– 183 –

Safety Cautions

Before installation work, read thoroughly this “Safety Cautions” to install the air conditioner correctly.

This “Safety Cautions” describes the important contents concerned to the safety. Be sure to keep in mind these items. Symbols and meanings are as described below.

WARNING

Indicates “User may be dead or seriously injured (*1) if it is incorrectly used.”

 

 

CAUTION

Indicates “It is assumed that user may be injured (*2) or property damage (*3) may occur if it is

incorrectly used.”

 

 

 

*1: “Serious injury” means a disease which has an after-effect or requires hospitalization or long-term going to the hospital for treatment, such as loss of sight, burn (by high temperature or low temperature), electric shock, fracture, poisoning, etc.

*2: “Injury” means hurt, burn, electric shock, etc. which does not require hospitalization or long-term going to the hospital for treatment.

*3: “Property damage” means enlarged damage concerned to house, household effects, domestic animal, pet, etc.

Explanation of picture symbols

indicates prohibition (prohibited action).

The concrete prohibited action is indicated with picture or sentence in or near the picture symbol.

indicates that the forced instructed action (Act necessarily).

The concrete instructed action is indicated with picture or sentence in or near the picture symbol.

indicates an item with care.

Install the filter sold separately.

Setup of fan when building in the filter sold separately:

Necessary at initial installation only

Two methods are provided for setup, one is to use a wired remote controller sold separately

SET DATA

CODE No.

 

 

 

and the other is to exchange the short plug on the indoor microcomputer P.C. board.

 

UNIT No.

 

SETTING

R.C. No.

 

 

 

 

 

 

 

[Using a wired remote controller sold separately]

4

 

 

2

(Procedure) Perform the setup while the equipment stops.

 

 

1 Push SET + CL +

buttons concurrently for 4 seconds or more.

6

 

UNIT

3

The firstly displayed unit No. is the master indoor unit address of the group control.

1

SET CL

 

In this time, the fan of the selected indoor unit only operates.

 

 

 

5

2

Every pushing UNIT

button, No. of the group control units are displayed in

*

Setup can be performed only by the

 

 

wired remote controller. If setup is not

 

order.

 

 

 

 

 

 

 

 

 

 

 

 

 

performed, air volume is decreased and

 

In this time, the fan of the selected indoor unit only operates.

 

 

3

 

 

dewing occurs.

 

 

 

 

 

 

 

Using set temperature

and

buttons, specify the item code “5d”.

Item code 5d

4

Using timer time

and

buttons, select from the set data.

 

 

Set data

 

Filter sold separately

 

 

 

 

For contents of the setup data, refer to the table at the right.

 

 

 

5

 

 

0000

 

Standard filter (At shipment)

Push SET

button.

 

 

 

 

 

 

 

 

 

 

 

 

 

High-efficiency filter (65%)

 

(When flashing display changes to lighting display, the setup completes.)

 

 

 

 

6

 

 

0001

 

(TCB-UFM11BE to UFM41BE)

 

 

 

 

 

 

 

 

Pushing

button returns the state to the normal stop state.

 

 

 

High-efficiency filter (90%)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TCB-UFH51BE to UFH81BE)

 

 

 

 

 

 

 

 

 

 

 

[Exchange of short plug on indoor microcomputer P.C. board]

The concrete item to be cautioned is indicated with picture or sentence in or near the picture symbol.

WARNING

CAUTION

• Do not put a plastic bag including filter on a place where

• Install the suction grille surely to the main unit.

hands of a small child can reach.

If an incomplete installation is performed,

If the child puts the bag on his head, it may seal

falling of the suction grille causes an injury.

his mouth or nose resulting in choke of death.

 

Specifications

Deodorant filter

TCB-

TCB-

TCB-

TCB-

Ammonium filter

TCB-

TCB-

 

TCB-

TCB-

model name

DF11BE

DF21BE

DF31BE

DF41BE

model name

UFH11BE-AM

UFH21BE-AM

UFH31BE-AM

UFH41BE-AM

 

 

 

 

 

 

 

 

 

 

 

Conformed air

561BT

801BT

1101BT

Conformed air

561BT

 

801BT

1101BT

conditioner model name

to

conditioner model name

 

to

 

 

 

1401BT

 

 

 

 

1401BT

 

 

 

 

 

 

 

 

 

 

 

Quantity

1

1

2

2

Quantity

1

1

 

2

2

 

 

 

 

 

 

 

 

 

 

 

Initial deodorant

 

85%

 

Initial deodorant

 

95%

 

 

performance

 

 

performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deodorant durable

 

Approx. 9 months

 

Deodorant durable

 

Approx. 15 months

 

performance

 

 

performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To exchange the static pressure, there is a method other than the abovementioned method by wired remote controller, which is to shift the short plug on the indoor microcomputer P.C. board as shown in the following table. Adopt this method in case of using a wireless remote controller, etc.

*However, after exchanging once, be careful to shift the short plug to the standard position (At shipment) in order to return to the standard setup (follow to E2PROM setup) though the setup for high static-pressure 1, high static-pressure 2, or low static-pressure can be arbitrarily performed. It is necessary to rewrite data from the wired remote controller sold separately in the set data “0000”.

Select with shifting of the short plug on the indoor unit microcomputer P.C. board.

Short plug position (CN112, CN111, CN110 from the left)

*1 Resistance of high- efficiency filter 65 and 90, deodorant filter, or ammonium filter is equivalent to 30Pa. Therefore, set the resistance (external static pressure) of a duct to be connected to 40Pa.

Short plug position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

Filter sold separately

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

static

 

 

 

 

 

 

 

 

 

 

 

 

pressure

 

 

 

 

 

Short Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCB-DF11,

TCB-DF11,

CN112 CN111 CN110

40Pa

Standard filter

 

 

 

 

 

 

 

 

 

 

Standard

(At shipment)

 

 

 

 

 

 

 

 

 

 

(At shipment)

Zeolite-3G deodrant filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure 1

*1

CN112 CN111 CN110

70Pa

 

 

 

 

 

 

 

 

 

 

 

 

High static-

High-efficiency filter 65

 

 

 

 

 

 

 

 

 

 

 

 

High-efficiency filter 90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Pa

Deodorant filter

21,

21,

 

 

 

 

 

 

 

 

 

 

 

Ammonium filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN112 CN111 CN110

 

 

31,

31,

 

 

 

 

 

 

 

 

 

 

High static-

——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure 2

41BE-AM

41BE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN112 CN111 CN110

20Pa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low static-

——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEBF-E

Page 107
Image 107
Balcar R410A Concealed Duct type, 183, Deodorant Filter, Ammonium Filter, Installation of filter sold separately, Notes