Balcar R410A Concealed Duct type, 182, High-EfficiencyFilter, Safety Cautions, Specifications

Models: R410A

1 109
Download 109 pages 54.47 Kb
Page 106
Image 106
High-Efficiency Filter

Concealed Duct type

High-Efficiency Filter

Installation Manual

High-Efficiency filter (65%)

Model: TCB-UFM11BE

 

TCB-UFM21BE

 

TCB-UFM31BE

 

TCB-UFM41BE

High-Efficiency filter (90%)

Model: TCB-UFH51BE

 

TCB-UFH61BE

 

TCB-UFH71BE

 

TCB-UFH81BE

NOTES

For installation of the filter, refer to the rear side of this manual.

Keep this Manual with Owner’s Manual.

Installation of high-efficiency filter

 

 

1 Remove the air filter, and install high-efficiency filter to the

 

 

suction port.

 

High-efficiency

Push the high-efficiency filter completely up to the end.

 

filter

 

 

Check that the rear side is hanged to the hook.

 

 

2 Install the air filter

 

Hook

Be sure to fix the air filter with clamps in order to prevent falling.

Indoor unit

(Clamps are attached to the indoor unit.)

 

High-efficiency

NOTE

 

filter

 

 

These filter cannot be reused even if it is washed.

 

Air filter

 

 

To install a filter sold separately, be sure to set the fan referring the following description.

* The filter sold separately cannot be installed to an air conditioner built in with auxiliary electric heater.

Setup of fan when building in the high-efficiency filter:

Necessary at initial installation only

Safety Cautions

Before installation work, read thoroughly this “Safety Cautions” to install the air conditioner correctly.

This “Safety Cautions” describes the important contents concerned to the safety. Be sure to keep in mind these items. Symbols and meanings are as described below.

WARNING

Indicates “User may be dead or seriously injured (*1) if it is incorrectly used.”

 

Indicates “It is assumed that user may be injured (*2) or property damage (*3) may occur if it is

Two methods are provided for setup, one is to use a wired remote controller sold separately

SET DATA

CODE No.

 

 

 

and the other is to exchange the short plug on the indoor microcomputer P.C. board.

 

UNIT No.

 

SETTING

R.C. No.

 

 

 

 

 

 

 

[Using a wired remote controller sold separately]

4

 

 

2

(Procedure) Perform the setup while the equipment stops.

 

 

6

 

 

1 Push SET + CL +

buttons concurrently for 4 seconds or more.

 

 

3

1

 

UNIT

The firstly displayed unit No. is the master indoor unit address of the group control.

SET CL

 

In this time, the fan of the selected indoor unit only operates.

 

 

 

5

– 182 –

CAUTION

incorrectly used.”

 

*1: “Serious injury” means a disease which has an after-effect or requires hospitalization or long-term going to the hospital for treatment, such as loss of sight, burn (by high temperature or low temperature), electric shock, fracture, poisoning, etc.

*2: “Injury” means hurt, burn, electric shock, etc. which does not require hospitalization or long-term going to the hospital for treatment.

*3: “Property damage” means enlarged damage concerned to house, household effects, domestic animal, pet, etc.

Explanation of picture symbols

indicates prohibition (prohibited action).

2 Every pushing UNIT button, No. of the group control units are displayed in order.

In this time, the fan of the selected indoor unit only operates.

3 Using set temperature Installation of high-efficiency filter and – 182 – buttons, specify the item code “5d”.

4 Using timer time TCB-UFH51, and TCB-UFM11, buttons, select from the set data.

For contents of the setup data, refer to the table at the right.

5

Push SET

button.

6

(When flashing display changes to lighting display, the setup completes.)

Pushing

button returns the state to the normal stop state.

*Setup can be performed only by the wired remote controller. If setup is not performed, air volume is decreased and dewing occurs.

• Item code 5d

Set data

Filter sold separately

0000

Standard filter (At shipment)

 

High-efficiency filter (65%)

0001

(TCB-UFM11BE to UFM41BE)

High-efficiency filter (90%)

 

 

(TCB-UFH51BE to UFH81BE)

 

 

The concrete prohibited action is indicated with picture or sentence in or near the picture symbol.

[Exchange of short plug on indoor microcomputer P.C. board]

indicates that the forced instructed action (Act necessarily).

The concrete instructed action is indicated with picture or sentence in or near the picture symbol.

indicates an item with care.

The concrete item to be cautioned is indicated with picture or sentence in or near the picture symbol.

WARNING

CAUTION

• Do not put a plastic bag including filter on a place where

• Install the suction grille surely to the main unit.

hands of a small child can reach.

If an incomplete installation is performed,

If the child puts the bag on his head, it may seal

falling of the suction grille causes an injury.

his mouth or nose resulting in choke of death.

 

Specifications

High-efficiency filter

TCB-

TCB-

TCB-

TCB-

High-efficiency filter

TCB-

TCB-

TCB-

TCB-

(65%) model name

UFM11BE

UFM21BE

UFM31BE

UFM41BE

(90%) model name

UFH51BE

UFH61BE

UFH71BE

UFH81BE

 

 

 

 

 

 

 

 

 

 

Conformed air

 

 

 

1101BT

Conformed air

 

 

 

1101BT

561BT

801BT

to

561BT

801BT

to

conditioner model name

conditioner model name

 

 

 

1401BT

 

 

 

1401BT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantity

1

1

2

2

Quantity

1

1

2

2

 

 

 

 

 

 

 

 

 

 

Dust collecting effect

 

Color test 65%

 

Dust collecting effect

 

Color test 90%

 

 

 

 

 

 

 

 

 

 

 

Operation time

 

2500 hours

 

Operation time

 

1800 hours

 

 

 

 

 

 

 

 

 

 

 

To exchange the static pressure, there is a method other than the abovementioned method by wired remote controller, which is to shift the short plug on the indoor microcomputer P.C. board as shown in the following table. Adopt this method in case of using a wireless remote controller, etc.

*However, after exchanging once, be careful to shift the short plug to the standard position (At shipment) in order to return to the standard setup (follow to E2PROM setup) though the setup for high static-pressure 1, high static-pressure 2, or low static-pressure can be arbitrarily performed. It is necessary to rewrite data from the wired remote controller sold separately in the set data “0000”.

Select with shifting of the short plug on the indoor unit microcomputer P.C. board.

Short plug position (CN112, CN111, CN110 from the left)

*1 Resistance of high- efficiency filter 65 and 90, deodorant filter, or ammonium filter is equivalent to 30Pa. Therefore, set the resistance (external static pressure) of a duct to be connected to 40Pa.

Short plug position

 

 

 

 

 

 

 

 

 

 

 

 

External

Filter sold separately

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

static

 

 

 

 

 

 

 

 

 

 

pressure

 

 

 

Short Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN112 CN111 CN110

40Pa

Standard filter

 

 

 

 

 

 

 

 

 

 

Standard

(At shipment)

 

 

 

 

 

 

 

 

 

 

(At shipment)

Zeolite-3G deodorant filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN112 CN111 CN110

70Pa

*1

 

 

 

 

 

 

 

 

 

 

High static-

High-efficiency filter 65

 

 

 

 

 

 

 

 

 

 

High-efficiency filter 90

 

 

 

 

 

 

 

 

 

 

pressure 1

 

 

 

 

 

 

 

 

 

 

Deodorant filter

 

 

 

 

 

 

 

 

 

 

 

Ammonium filter

CN112 CN111 CN110

100Pa

 

 

 

 

 

 

 

 

 

 

 

 

 

High static-

——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CN112 CN111 CN110

20Pa

 

 

 

 

 

 

 

 

 

 

 

 

 

Low static-

——

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCB-UFH51,

TCB-UFM11,

61, 71, 81BE

21, 31,41BE

UFBE-E

Page 106
Image 106
Balcar R410A Concealed Duct type, 182, High-EfficiencyFilter, Installation of high-efficiencyfilter, Safety Cautions