RS485 setup (RS485 SETUP)

Refer to the step (7) in 2.5.

Data port setup (DATA PORT SETUP)

The settings relating to the serial data communication can be configured on "DATA PORT SETUP" of "COMMUNICA- TION SETUP" on the "WJ-RT208 SETUP MENU".

(1)Press the [MENU] button. The "WJ-RT208 SETUP MENU" will be displayed.

WJ-RT208 SETUP MENU

SYSTEM MANAGEMENT

SEARCH

REC&EVENT SETUP

PTZ SETUP

CAMERA SETUP

COMMUNICATION SETUP

REPORT

USER INFORMATION

DATA MANAGEMENT

(2)Move the cursor onto "COMMUNICATION SETUP" and press the [SET] button.

The "COMMUNICATION SETUP" menu will be dis- played.

COMMUNICATION SETUP

NETWORK SETUP

RS485 SETUP

DATA PORT SETUP

(3)Move the cursor onto "DATA PORT SETUP" and press the [SET] button.

The "DATA PORT SETUP" menu will be displayed.

 

DATA PORT SETUP

 

 

 

 

 

 

 

 

 

 

 

Unit Address (System)

 

001

 

 

 

 

 

 

 

Baud Rate

 

 

 

9600

 

 

 

 

 

 

 

 

Data Bit

 

 

 

8

 

 

 

 

 

 

 

Parity

 

 

 

None

 

 

 

 

 

 

 

 

Stop Bit

 

 

 

1

 

 

 

 

 

 

 

Retry Timing

 

 

 

Off

 

 

 

 

 

 

Alarm Data

 

 

 

1s

 

 

 

 

 

 

Channel No.

 

 

 

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

Cancel

 

 

 

 

 

 

 

 

 

(4) Configure the following setup items.

"Unit Address (System)"

A unit address (System) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data.

Numbers, "001"-"099", are to be assigned as the unit addresses to the system devices.

"Baud Rate"

Select the communication speed for data transmission with a connected device from the following.

2400/4 800/9 600/19 200/38 400 bps

"Data Bit"

It is impossible to change the value for this setting.

8(bit)

"Parity"

Select a method to check a transmission error at com- munication from the following.

"None": No parity check

"Even": Even parity

"Odd": Odd parity

"Stop Bit"

Select a stop bit from the following.

1bit/2 bit

"Retry Timing"

Select a retransmission interval for when data reception is not confirmed from the following.

OFF/100 ms/200 ms/400 ms/1 000 ms

"Alarm Data"

Select a method to inform the connected controller of an event occurrence from the following.

"Off": Does not function.

"0s": Informs the controller every time an event is detected.

"1s/5s": Informs the controller when a specified time has passed after detecting an event.

"Channel No."

It is possible to assign a number to each camera chan- nel to operate cameras using the controller compatible with PS·Data.

Do the following to assign numbers to the camera chan- nels.

(1)Move the cursor onto "Channel No." and press the [SET] button.

The "Channel No." menu will be displayed.

41

Page 41
Image 41
Panasonic WJ-RT208 manual RS485 setup RS485 Setup, Data port setup Data Port Setup