Panasonic WJ-RT208 manual Ntsc

Models: WJ-RT208

1 62
Download 62 pages 32.75 Kb
Page 34
Image 34

System setup (SYSTEM SETUP)

Item

Descriptions and remarks

Selectable parameters

[Default Setting]

 

 

 

 

 

 

"Power On Rec."

Recording will automatically start when the power is turned on.

"On/Off"

 

 

 

"Off"

 

 

 

 

"Seq. Dwell"

Sequential changeover time intervals.

02 - 30, 05

 

 

 

 

"Video Format"

The video output format is fixed to the NTSC system. Therefore, the user

"NTSC"

 

 

cannot set the settings.

 

 

 

 

 

 

"Overwrite"

Even when "On" is selected for "Overwrite", recording will not be per-

"On/Off"

 

 

formed to protect data from overwriting for the days set on "Rec. Reserve"

"On"

 

 

of "CAMERA SETUP" unless the set days have passed.

 

 

 

 

 

"Status Display"

It is possible to conceal information such as the channel name that is dis-

"All/Stat/None/Name"

 

played on the screen.

"All"

 

 

 

 

 

"Keylock Time"

Even after the lapse of the preset time, the key lock does not function if

005 - 999

600

 

recording data is being backed up.

 

 

 

After the lapse of the preset time counted after the completion of record-

 

 

 

ing data backup, the key will be automatically locked.

 

 

 

 

 

 

"Keylock Buzz"

When setting is made at "On" and a password is wrongly keyed in three

"On/Off"

"On"

 

times continuously, the buzzer begins to sound for one minute.

 

 

 

 

 

 

"Alarm Buzz"

Buzzer "On/Off" is set up.

"On/Off"

"Off"

 

 

 

 

"Pre Recording"

The time period for pre recording can differ according to the order of

"On/Off"

"Off"

 

recording start. The minimum time period is 5 seconds. (Changeable with

 

 

 

"I Frame Inter.", "Rec. Quality", and "Stream Type")

 

 

 

When changing this setting, it is necessary to stop recording and discon-

 

 

 

nect all network connections.

 

 

 

Note: When Pre Recording is set at "On", the pre-recorded image data

 

 

 

may be separated to different data groups.

 

 

 

 

 

"Rec. Quality"

If settings of "Rec. Quality", "I Frame Inter.", "Stream Type", and "Frame

"SP Fine/Fine/Good/

 

Rate" are changed in the middle of recording, recording will stop and

Normal/Extended"

 

then will resume. Then the setting values become effective.

"Normal"

 

 

If recording is not stopped, the new setting becomes effective after the

 

 

 

lapse of the time period preset with "RECORD LENGTH".

 

 

 

 

 

 

"I Frame Inter."

Playback is delayed if the setting value for "I Frame Inter." is too high. We

01 - 15

 

 

recommended using a default value. When changing this setting, it is

04

 

 

necessary to stop recording and disconnect the network connections.

 

 

 

Implement the settings of "I Frame Inter." after the pre-recording setting

 

 

 

has been set at OFF.

 

 

 

 

 

"Resolution"

Resolution of image data output from the VGA interface

800 x 600 or 1024 x 768

 

 

[800 x 600]

 

 

 

 

"Alarm Spot"

When an alarm goes off, the screen of the occurring alarm is displayed in

On/Off

"Off"

 

the single-spot mode.

 

 

 

 

 

 

"Stream Type"

When the setting is made at "VBR", there may be a difference in recording

CBR/VBR

 

 

length. If the recording time need be in higher preference, the setting

"CBR"

 

 

should be made at "CBR". If screen changes seem to be extreme, the set-

 

 

 

ting made at "VBR" is preferable.

 

 

 

 

 

 

"Terminal Input"

N.O.: Alarm is started with a low-level signal.

N.O./N.C.

 

 

N.C.: Alarm is started with a high-level signal.

"N.O."

 

 

 

 

"Frame Rate"

The frame rate set at "Full" is 25 frames/second.

"Full, 1/2F, 1/4F, 1/8F, 1/16F"

 

 

"Full"

 

 

 

 

 

Note: When "Terminal Input" is set at "N.C.", an alarm unit of "N.O." should be connected to the alarm port of this unit. If no con- nections are made, the alarm port will be "N.O." (normally open) and will continue receiving alarm signals at all times.

34

Page 34
Image 34