Panasonic WV-NS202 User authentication, Default: OFF User name, Password Retype password

Models: WV-NS202

1 79
Download 79 pages 20.1 Kb
Page 54
Image 54
[User authentication]

Configure the settings relating to the authentication [Authentication setup]

The settings relating to the authentication such as users and PCs restrictions for accessing the camera can be con- figured on this page.

The "Authentication setup" page has 2 tabs of the [User] tab and the [Host] tab.

Configure the settings relating to the user authentication [User]

Click the [User] tab on the "Authentication setup" page. (page 15)

The settings relating to the user authentication can be configured on this page. Up to 16 users can be registered.

Note:

When user authentication (authentication error) has failed to pass 8 times within 30 seconds using the same IP address (PC), access to the camera will be denied for a while.

[User authentication]

Select "ON" or "OFF" to determine whether or not to authenticate the users.

Default: OFF

[User name]

Enter a user name.

Number of characters for the user name: 1 - 32 char-

acters

Default: None (blank)

[Password] [Retype password]

Enter the password.

Number of characters for the password: 4 - 32 char-

acters

Default: None (blank)

Note:

When the user name already in use is entered and the [SET] button is clicked, the respective user infor- mation will be overwritten.

[Access level]

Select the access level of the user from the following.

1.Administrator: Allowed all available operations of the camera.

2.Camera control: Allowed to display images from the camera and to control the camera. The camera set- ting configuration is unavailable.

3.Live only: Only displaying live images is available. The camera setting configuration and camera con- trol are unavailable.

Default: 3. Live only

Note:

By clicking [i] of "User name check", the registered user can be selected and the selected user’s infor- mation can be checked.

The registered user will be displayed with the access level. (Example: admin [1])

To delete the registered user, click the [DEL] button after selecting the user to be deleted.

Important:

If all users whose access level is "1. Administrator" are deleted, it will be impossible to configure the set- tings.

54

Page 54
Image 54
Panasonic WV-NS202 User authentication, Default: OFF User name, Password Retype password, Access level