Panasonic WV-NS202 Alarm output terminal setup, AUX name, Alarm output setup, Default: OPEN

Models: WV-NS202

1 79
Download 79 pages 20.1 Kb
Page 47
Image 47
■Alarm output terminal setup

Configure the settings relating to the alarm out connector

Click the [Alarm] tab on the "Alarm setup" page. (page 15)

Alarm output terminal setup

The settings relating to the alarm out connector can be configured in this section. The settings for the alarm output terminal can be configured only when "Alarm output" is selected for "Terminal alarm 2" of "Alarm setup". Refer to pages 43, 44 and 46 for further information about the settings relating to the alarm, the camera action at an alarm occurrence and the alarm image.

[Alarm output setup]

Select "ON" or "OFF" to determine whether or not to output the alarm signals to the alarm output terminal when an alarm is detected.

Default: OFF

[External terminal output setup]

Select "Latch" or "Pulse" for the alarm output terminal at an alarm occurrence.

Latch: When an alarm is detected, the alarm output ter- minal will be in the state selected for "Alarm output" until the alarm occurrence indication button is clicked.

Pulse: When an alarm is detected, the alarm output ter- minal will be in the state to the "Alarm output" setting for the period set for "Pulse width".

Default: Latch

[Alarm output]

Select "Open" or "Close" to determine whether to open or close the alarm output terminal when outputting the alarm signals.

OPEN: The alarm output terminal will open when out- putting the alarm signals. (Normally close)

CLOSE: The alarm output terminal will close when out- putting the alarm signals. (Normally open)

Default: OPEN

Note:

When "OPEN" is selected, the alarm signal will be output for around 20 seconds when the power of the camera is turned on.

[Pulse width]

When "Pulse" is selected for "Alarm output", select an alarm output terminal duration from the following. Available pulse width: 1 - 120 sec

Default: 1 sec

AUX name

The names of "AUX", "OPEN" and "CLOSE" on the "Live" page can be changed.

[AUX (Up to 10 characters)]

Enter the name for "AUX" on the "Live" page.

[OPEN (Up to 5 characters)]

Enter the name for "OPEN" of "AUX" on the "Live" page.

[CLOSE (Up to 5 characters)]

Enter the name for "CLOSE" of "AUX" on the "Live" page.

47

Page 47
Image 47
Panasonic WV-NS202 Alarm output terminal setup, AUX name, Alarm output setup, Default: OFF External terminal output setup