For example, to print a string of bar code data
with function code F2 as the fourth character...
123(F2)5678
send this string of characters...
| 123~1295678 |
|
|
ASCII Code | Function Code |
|
|
~134 | F1 |
|
|
~129 | F2 |
|
|
~128 | F3 |
|
|
~132 | F4 |
|
|
Two additional bar codes are supported as extensions to both UPC and EAN bar codes.
+2 Send exactly two digits for this bar code.
+5 Send exactly six digits (a
L i n e F i e l d
The message structure below transmits a line field. This data stream defines the bit map to form a graphic line field. Use the line field to emphasize data by printing a line or box.
You can have up to 100 line images. The line record can be placed in a format data stream anywhere following the format header record. Lines are counted as fields, just like text or bar code fields. When determining the number of fields in your format, count each line as a separate field.
Syntax L##, ROW, COLUMN, DIRECTION, STOP, THICKNESS p