Paxar 9474 manual Density, Bfont

Models: 9474

1 96
Download 96 pages 24.03 Kb
Page 27
Image 27

The zero point is 1.5 mm or 0.060 inches from the bottom of the supply. The bottom of the supply is the edge that exits the printer first.

This value is measured in tenths of millimeters (TOMMS) and must be less than the maximum length of the supply.

 

Values:

0-2032

 

NOTE: The minimum row location for serial bar code fields is

 

 

23 (0.09 inches)

COL

One to four digits to define the column location of the field on

 

the supply. This is the distance from the guide edge zero

 

point at the left edge of the supply and the left edge of the

 

field.

 

 

The zero point is 1.5 mm or 0.060 inches from the left edge of

 

the supply.

 

The unit of measurement is tenths of millimeters. The range

 

must be less than the maximum width of the supply.

 

Values:

0-1016(0 to 4 inches)

DENSITY

One digit for the bar code density for Interleaved 2 of 5, Code

 

128, MSI, Code 39, and UPC/EAN bar codes.

 

Values:

1-5

 

Some bar codes do not support all 5 values.

 

For the actual densities for these values, see Chapter 5,

 

"Quick References."

BFONT

One digit indicating which bar code font to use.

Values: 1 UPC-A

2UPC-E

3Interleaved 2 of 5

4 Code 39

5 Codabar

6 EAN-8

7 EAN-13

8 Code 128

9 MSI

10 UPC/EAN+2

11 UPC/EAN+5

Message Structures 3-13

Page 27
Image 27