Care and maintenance
10.07 Checking the air pressure
2
1
Fig. 10 - 07
●Before each use of the machine, check the air pressure on gauge 1.
●The gauge must display a pressure of 6 bar.
●If necessary, alter the pressure to this level.
●To do so, lift button 2 and turn it so that the gauge shows a pressure of 6 bar.
●Press button 2 back down again.
10.08 Emptying / Cleaning the water container of the air filter
2
max.
1
Fig. 10 - 08
Turn the machine off!
Remove the
Emptying the water trap
●Water trap 1 empties itself automatically when the
Cleaning the filter
●Unscrew water trap 1 and filter 2.
●Clean the filter with compressed air or with isopropyl alcohol, Part number
●Screw filter 2 back in and water trap 1 back on.
10 - 5