Adjustment
11.04.05 Centering the needle in the needle holeRequirement
With the stitch length set at „0“, the needle must enter the needle hole exactly in the middle.
4
3
7
6
8
5
1
9
2
Fig. 11 - 05
● Unscrew vibrating presser 1 and presser foot 2.
● Set stitch length „0“ and bring the needle bar to its TDC.
●Insert a new needle. Loosen screws 3, 4, 5 and 6.
●Position the needle directly over the bottom feed dog by turning the handwheel.
●Move needle bar frame 7 in accordance with the requirement.
●Tighten screws 3, 4 and 5.
●Position stop 8 so that it is touching needle bar frame 7 and tighten screw 6.
The movement of needle bar frame 7 in guide 9 and of the top feed drive bars must not be stiff.
11 - 6