Adjustment

11.05.06 Engaging lever

Requirement

With the needle bar at TDC and with control lever 3 at starting position, there must be a distance of approx. 0.3 mm between bolt 4 and the outer diameter of control cam 5.

34

5

3

5

1

2

Fig. 11 - 22

● Bring the needle bar toTDC by turning the handwheel.

● Turn screw 1 (nut 2) in accordance with the requirement.

Carry out a check by tapping control lever 3.

11 - 25