Adjustment
4 1
2
1 5
7 | 5 6 |
3
Fig. 11 - 08
adjustable clamp is touching the needle bar bearing.
● Position the hook point at the middle of the needle, taking care to ensure that the needle is not pressed by needle guard 7.
●While ensuring that bevel pinion 5 is not too close, and that the hook does not exhibit too much play, tighten screws 2.
●On machines with automatic thread trimmer
●Adjust the needle height in accordance with requirement 2 (see also chapter 11.04.04).
●Align needle guard 7 in accordance with requirement 3.
Bei der PFAFF 1246 ist nach Veränderung des Nadelabstandes unbedingt die
Verbindungsstange zum Fadenabschneider (siehe auch Kap.11.05.10)
neu zu justieren.
11 - 10