Adjustment

11.04.10 Lifting motion of the top feed

Requirement

When presser foot 1 is resting on the needle plate, the vibrating presser foot 4 and the point of the needle must both reach the needle plate at the same time when the top feed stroke is set at maximum.

23

1

4

Fig. 11 - 10

● Allow presser foot 1 to rest on the needle plate.

● Loosen screws 2 until feed lifting eccentric 3 can be turned on its shaft with difficulty.

Turn feed lifting eccentric 3 in accordance with the requirement.

Tighten screws 2.

Carry out a check in accordance with the requirement.

11 - 12