Adjustment
11.05.04 Engaging solenoidRequirement
In needle rise position and with engaging solenoid 5 activated, there must be a distance of 0.3 mm between engaging lever 2 and pawl 3.
3 4 5
1 | 5 | 2 |
|
|
0.3 mm
Fig. 11 - 20
● Bring the machine to needle rise position by turning the handwheel.
● Loosen screw 1 until the engaging solenoid can be turned with difficulty.
●Manually activate engaging lever 2 so that pawl 3 engages.
●Press magneto inductor 4 as far as possible into solenoid housing 5 and move both the solenoid housing and the magneto inductor in accordance with the requirement.
●In this position tighten screw 1.
11 - 23