Adjustment

11.05.04 Engaging solenoid

Requirement

In needle rise position and with engaging solenoid 5 activated, there must be a distance of 0.3 mm between engaging lever 2 and pawl 3.

3 4 5

1

5

2

 

 

0.3 mm

Fig. 11 - 20

● Bring the machine to needle rise position by turning the handwheel.

● Loosen screw 1 until the engaging solenoid can be turned with difficulty.

Manually activate engaging lever 2 so that pawl 3 engages.

Press magneto inductor 4 as far as possible into solenoid housing 5 and move both the solenoid housing and the magneto inductor in accordance with the requirement.

In this position tighten screw 1.

11 - 23