Adjustment

11.05.05

Release trip

Requirement

In needle rise position and with control lever 4 engaged, there must be a distance of approx. 0.3 mm between the bolt of the control lever and the base of the cam track.

0.3 mm

5

4

6

4

2

3

6

1

Fig. 11 - 21

● Bring the machine to needle rise position by turning the handwheel. ● Manually activate engaging lever 1 so that pawl 2 engages.

Taking care to ensure that screw 3 is still loose, press control lever 4 down to the base of the track of control cam 5.

Maintaining this position, lightly tighten screw 3 while bringing release trip 6 into a resting position against engaging lever 1 and laterally against control lever 2 in the direction of the arrow.

By lightly tapping on release trip 6 in the direction of the arrow, while simultaneously tapping control lever 4, create a distance between the bolt and the base of the cam track which corresponds with the requirement.

In this position tighten screw 3.

Carry out a check in accordance with the requirement.

11 - 24