Adjustment

11.04.04 Pre-adjusting the needle height

Requirement

With the needle bar at BDC, the distance between the needle bar and the needle plate must be 15 mm.

2 1

15 mm

Fig. 11 - 04

● Move needle bar 1 (screw 2) in accordance with the requirement without moving it

laterally.

11 - 5