Adjustment
11.04.04 Pre-adjusting the needle height
Requirement
With the needle bar at BDC, the distance between the needle bar and the needle plate must be 15 mm.
2 1
15 mm
Fig. 11 - 04
● Move needle bar 1 (screw 2) in accordance with the requirement without moving it
laterally.