Step 5: **Configuration Setup & Enter Factory Mode ** for "write EDID data"

1.Click icon from the tool bar to bring up the Configuration Setup windows again. Then, select "Software DDC only" as shown in Fig. 16. Click "OK".

Fig. 16

If you do not select "Software DDC only", when you execute "write EDID", it will bring up an error message as below.

Step 6: Write DDC data

1.Click (Write EDID) icon from the tool bar to write DDC data. Bring up "Writing 0%~100%, ready" a progressing bar on the left down corner.

2.Click (Read EDID) to confirm it.

Step 7: Confirm Serial Number in User Mode

 

1. Press the

button to turn off the monitor. Press the

button

again to turn on the monitor.

 

2.Press the button to bring up the OSD Main Menu.

3. Press the button to select Extra Controls, press the button to confirm your selection.

4.Confirm the Serial Number "123456" is updated as shown in Fig. 18.

To access factory mode

1.Turn off monitor (don't turn off PC)

2.Press " " and " " simultaneously on the front control

panel,then press " ",wait till the OSD menu with characters V30 10T5 P V2.01 20030110 (below OSD menu)" come on the screen of monitor.

Fig. 18

Step 8: Save DDC data

Sometimes, you may need to save DDC data as a text file for using in other IC chip. To save DDC data, follow the steps below:

1.Click (Save) icon (or click "file"-> "save as") from the tool bar and give a file name as shown in Fig. 19.

The file type is EDID301 file (*.ddc) which can be open in WordPad. By using WordPad, the texts of DDC data & table (128 bytes, hex code) can be modified. If DDC TEXTS & HEX Table are completely correct, it can be saved as .ddc flie to re-load it into EEPROM for DDC Data application.

Fig. 17

Factory

Mode

Indicator

MODEL SELECT

V30 107T5 P V.2.01 20030110

Fig. 19

107T5 V30

If OSD menu disappears on the screen of monitor, press " " again (anytime), then the OSD menu comes on the screen again.

If you do not access "Factory mode", when you execute "write EDID", it will bring up an error message as below.

2.Click Save.