Incorrect operations are often mistaken for trouble and malfunctions. If you think that there is something wrong with this component, check the points below. Sometimes the trouble may lie in another component. Investigate the other components and electrical appliances being used. If the trouble cannot be rectified even after exercising the checks listed below, ask your nearest Pioneer authorized service center or your dealer to carry out repair work.

Power

Symptom

Cause

Remedy

The power does not turn on.

• The power plug is disconnected.

• Connect the power plug to the wall outlet.

 

 

 

 

• The protection circuit may have been

• Disconnect the power plug from the outlet, and insert

 

activated.

again.

 

 

 

• Something is obstructing the rear panel fan. • Unplug the receiver from the wall and call a Pioneer-

 

 

authorized independent service company.

 

 

 

The receiver suddenly switches

• The speaker wires are frayed or sticking out

• Reinsert the speaker wires, making sure there are no

off.

of the jack, and are touching the back of the

stray strands of wire and that they are inserted fully.

 

receiver or another set of wires.

 

 

 

 

 

• The receiver has a serious problem.

• Unplug the receiver from the wall and call a Pioneer-

 

 

authorized independent service company.

During loud playback the power suddenly switches off.

The protection circuit has been activated because the lowest actual impedance of the speakers (as opposed to the speakers rated impedance) is dangerously low.

Turn down the volume.

When its convenient, go to Acoustic Calibration EQ on page 61 and lower the 63 Hz and 125 Hz equalizer levels using the manual setting.

Turning the digital safety feature on may allow you to turn up the volume a little more. To switch between SAFETY 1 (medium effect), SAFETY 2 (more effect) and SAFETY OFF, put the receiver into standby, then press the

STANDBY/ON button while holding down the OPTION button on the front panel. If the power switches off even with SAFETY 2 switched on, turn down the volume.

AMP ERR blinks in the display,

• The receiver has a serious problem.

then the power automatically

 

switches off.

 

After about a minute (you won’t be able to switch the unit on during this time), switch the receiver back on. If the message persists, call a Pioneer-authorized independent service company.

FAN STOP blinks in the display, then the power automatically switches off.

Something is obstructing the rear panel fan. • Remove the obstruction and try switching the receiver back on. If the fan is still not working, or you can’t remove the object, unplug the receiver from the wall and call a Pioneer-authorized independent service company.

• The fan is malfunctioning.

• Unplug the receiver from the wall and call a Pioneer-

 

authorized independent service company.

OVERHEAT blinks in the display and no sound is output.

The internal temperature of the unit has become too high.

After allowing the unit to cool down in a well-ventilated place, try switching the receiver back on. Make sure you follow the guidelines for improving heat dispersal in Ventilation on page 8.