Supply Pressure Table

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

5. Turn on the main gas supply line.

6.Check the supply gas pressure with the manometer and compare the reading to the supply gas pressure table to determine what the incoming gas pressure should be.

Supply Pressure Table

NAT

LP

 

 

7 to 9

11 to 13

 

 

NOTE: You cannot adjust the supply gas pressure at the unit. Anything over/under the recommended amount should be adjusted at the facility’s main gas line.

7.Shut off the main gas supply line.

8.Disconnect the manometer.

9.Remove the test fitting.

10. Apply Teflon paste to gas supply plug.

11.Reinstall gas supply plug with a 3/16 inch hex wrench.

12. Turn on the main gas supply line.

SG/SSH Series Service Manual

15

Page 15
Image 15
Pitco Frialator L22-345 manual Supply Pressure Table