Manual background

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

6.Check the supply gas pressure with the manometer and compare the reading to the Supply Gas Pressure table on page 52 to determine what the incoming gas pressure should be.

Supply Pressure Table

NAT

LP

 

 

7 to 9

11 to 13

 

 

NOTE: You cannot adjust the supply gas pressure at the unit. Anything over/under the recommended amount should be adjusted at the facility’s main gas line.

7.When adjustment is complete:

a.Shut off the main gas supply line

b.Disconnect manometer.

c.Remove the test fitting.

d.Apply Teflon paste to gas supply plug.

e.Reinstall gas supply plug with a 3/16 inch hex wrench.

f.Turn on the main gas supply line.

Taking a Manifold Gas Pressure Reading

1.Unscrew and remove the gas manifold plug with a 3/16 inch hex wrench.

3.Finish tightening the test fitting using a 7/16 inch open-ended wrench.

2. Finger tighten the test fitting into the test port

4. Connect the manometer.

SG/SSH Series Service Manual

52

Page 52
Image 52
Pitco Frialator L22-345 manual Taking a Manifold Gas Pressure Reading, Supply Pressure Table, 7 to