Pitco Frialator L22-345 manual Replacing the Return Switch

Models: L22-345

1 94
Download 94 pages 46.74 Kb
Page 72
Image 72
Replacing the Return Switch

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Return Switch

1.Disconnect all the wires from the gas valve, pilot, and SCB valve.

2.Drop the gas valve from the manifold.

3.Remove the two (2) screws, which hold the return valve handle, using a 5/16 inch socket.

5.Remove the two (2) screws, which hold the mounting bracket, using a 5/16 inch socket

6. Remove the mounting bracket.

4. Remove the return valve handle bracket.

7. Disconnect the mounting bracket wire from the pump box (not shown).

SG/SSH Series Service Manual

72

Page 72
Image 72
Pitco Frialator L22-345 manual Replacing the Return Switch