Replacing the Drain Line or Gasket

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Drain Line or Gasket

1.Remove one (1) screw on the drain line using a 7/16 inch wrench.

3. Slide off the drain manifold gasket.

2. Lift off the drain manifold clamp.

4.Slide out the drain line.

5.Reinstall the new drain line by following steps 1 through 4 in reverse to.