Pitco Frialator L22-345 manual Taking an Incoming Supply Gas Pressure Reading

Models: L22-345

1 94
Download 94 pages 46.74 Kb
Page 51
Image 51
Taking an Incoming Supply Gas Pressure Reading

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Accessing Fryer for Servicing

1. Shut off the main gas supply line.

2. Shut off the individual gas supply line.

Cleaning the Gas Valve Vent Tube

See “Cleaning the Gas Valve Vent Tube” on page 13.

Checking the Burner Manifold Gas Pressure

Taking an Incoming Supply Gas Pressure Reading

1. Unscrew and remove the gas supply plug with a

4. Connect the manometer.

3/16 inch hex wrench.

 

5. Turn on the main gas supply line.

2.Finger tighten the test fitting into the test port.

3.Finish tightening the test fitting using a 7/16 inch open-ended wrench.

SG/SSH Series Service Manual

51

Page 51
Image 51
Pitco Frialator L22-345 manual Taking an Incoming Supply Gas Pressure Reading, Accessing Fryer for Servicing