Adjusting Manifold Gas Pressure

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Adjusting Manifold Gas Pressure

1.Check the manifold gas pressure with the manometer and compare the reading to the manifold gas pressure table.

3.Insert flathead screwdriver into the cap and turn counter-clockwise to increase the gas pressure or clockwise to decrease the gas pressure.

Manifold Gas Pressure Table

NAT

LP

 

 

4.0”

10”

 

 

2.Insert a flathead screwdriver into the cap and turn counter-clockwise to remove it.

4. When adjustment is complete:

a. Disconnect the manometer. b. Remove the test fitting.

c. Reinstall the gas manifold plug. d. Reconnect solid state thermostat. e. Turn on gas supply line.

Adjusting Pilot Pressure

1.Remove pilot adjustment cap with Philips screwdriver.

2.Rotate adjuster clockwise to decrease and counter-clockwise to increase pilot flame.

3.Replace adjustment cap.

SG/SSH Series Service Manual

18

Page 18
Image 18
Pitco Frialator L22-345 manual Adjusting Manifold Gas Pressure, Adjusting Pilot Pressure, Manifold Gas Pressure Table