Adjusting Manifold Gas Pressure

1.Check the manifold gas pressure with the manometer and compare the reading to the Manifold Gas Pressure table.

3.Insert flathead screwdriver into cap and turn counter-clockwise to increase the gas pressure or clockwise to decrease the gas pressure.

Manifold Gas Pressure Table

NAT

LP

 

 

4.0”

10”

 

 

2.Insert a flathead screwdriver into the cap and turn counter-clockwise to remove it.

4. When adjustment is complete:

a. Shut off the gas supply line. b. Disconnect manometer.

c. Remove the test fitting.

d. Reinstall the gas manifold plug. e. Turn on gas supply line.