Pitco Frialator L22-345 Measuring Thermopile, Taking a Millivolt Reading, Thermopile mV Table

Models: L22-345

1 94
Download 94 pages 46.74 Kb
Page 54
Image 54
Measuring Thermopile

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Measuring Thermopile

Taking a Millivolt Reading

1. Make sure the multimeter is set to mV.

2.Touch the thermopile leads with the multimeter probes as shown.

Adjusting the Thermopile

1.Compare the multimeter reading to the Thermopile mV table.

Thermopile mV Table

Pilot lit

Pilot lit with burners on

PP1 to PP2

PP2 to TH2 approximately

600± mV

300 mV less than pilot alone

2.Insert a flathead screwdriver into the Pilot Adj. cap and turn counter-clockwise to remove it.

mV Gas Valve Resistance Readings Table

Pilot Valve

Main Valve

TH 1 to PP 2 10.4 Ω

TH 2 to PP 2 2.0 Ω

3.Insert flathead screwdriver into Pilot Adj. screw and turn counter-clockwise to increase the mV pressure or clockwise to decrease the mV pressure.

4. Disconnect the multimeter.

SG/SSH Series Service Manual

54

Page 54
Image 54
Pitco Frialator L22-345 Measuring Thermopile, Taking a Millivolt Reading, Adjusting the Thermopile, Thermopile mV Table