Replacing the Self‐Cleaning Burner Solenoid

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Self‐Cleaning Burner Solenoid

1.Remove the SCB flex tube fitting using a 1/2 inch open-ended wrench.

3.Disconnect the terminals using needle-nose pliers.

2.Remove the SCB valve inlet fitting using a 1/2 inch open-ended wrench.

4.Remove the two (2) elbows using a 1/2 inch open-ended wrench.

5.Follow steps 1 through 4 in reverse to reinstall SCB valve.