Pitco Frialator L22-345 manual Replacing the Pump Relay and Circuit Breaker

Models: L22-345

1 94
Download 94 pages 46.74 Kb
Page 75
Image 75
Replacing the Pump Relay and Circuit Breaker

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Pump Relay and Circuit Breaker

Replacing the Circuit Breaker

1.Disconnect the connections and power supply cords from the filter pump.

4.Remove all wires on the circuit breaker using needle-nose pliers.

2. Remove the pump box.

5. Squeeze the tabs on the circuit breaker and push it out.

3. Remove the circuit breaker from the pump box.

6. Reinstall the new circuit breaker by following steps 1 through 5 in reverse.

SG/SSH Series Service Manual

75

Page 75
Image 75
Pitco Frialator L22-345 manual Replacing the Pump Relay and Circuit Breaker, Replacing the Circuit Breaker