Replacing the Pump Relay

Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers

Replacing the Pump Relay

1.Remove the two (2) screws, which hold the pump relay, using a Phillips screwdriver.

2.Remove all wires on the pump relay using needle-nose pliers. See “Simplified Wiring Diagrams on page 89.

3.Remove the pump relay.

4.Reinstall the new pump relay by following steps 1 through 2 in reverse.