9 • Maintaining and Updating

5.Remove the wick, using the metal shield to gently pry it out of the moistener tank.

Metal shield

6.Drain the moistener tank over the front of the machine into a receptacle as shown here.

7.To clean the moistener tank, remove the E-Z Seal® Sealing Solution supply tube and wipe out the tank with E-Z Seal® solution.

Clean the wick by holding it under running water.

8.Push the supply tube back onto the moistener tank nozzle. Push the tube back on as far as it will go to prevent leaking.

9 - 8

SV61436 Rev. D

Page 144
Image 144