Configuration Files

Volume Persistence <volume/>

The user’s selection of the receive volume during a call can be remembered between calls. This can be configured per termination (handset, headset and hands-free/chassis). In some countries regulations exist which dictate that receive volume should be reset to nominal at the start of each call on handset and headset.

 

Permitted

 

 

Attribute

Values

Default

Interpretation

 

 

 

 

voice.volume.persist.handset

0, 1

0

If set to 1, the receive volume will be

 

 

 

remembered between calls.

voice.volume.persist.headset

0, 1

0

If set to 0, the receive volume will be reset

 

 

 

voice.volume.persist.handsfree

0, 1

1

to nominal at the start of each call.

 

 

 

 

Gains <gain/>

The default gain settings have been carefully adjusted to comply with the

TIA-810-A digital telephony standard.

Polycom recommends that you do not change these values.

Attribute

Default

 

 

voice.gain.rx.analog.handset

0

 

 

voice.gain.rx.analog.headset

0

 

 

voice.gain.rx.analog.chassis

0

 

 

voice.gain.rx.analog.chassis.IP_300

-6

 

 

voice.gain.rx.analog.chassis.IP_330

0

 

 

voice.gain.rx.analog.chassis.IP_430

0

 

 

voice.gain.rx.analog.chassis.IP_601

6

 

 

voice.gain.rx.analog.chassis.IP_650

0

 

 

voice.gain.rx.analog.ringer

0

 

 

voice.gain.rx.analog.ringer.IP_300

-6

 

 

voice.gain.rx.analog.ringer.IP_330

0

 

 

voice.gain.rx.analog.ringer.IP_430

0

 

 

voice.gain.rx.analog.ringer.IP_601

6

 

 